363-206-305 System Turnup:
Issue 3, June 2000 Page 1 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
NTP-008
Establish OC-1 Single-Homed FiberReach Access
via DDM-2000 OC-3 or OC-12 Backbone Ring
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
1.
!
WARNING:
Unterminated optical connectors may emit invisible laser
radiation. Avoid direct exposure to the beam. Do not view
beam with optical instruments. Use of controls or
adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
!
CAUTION:
DDM-2000 circuit packs contain static sensitive components
which can be damaged by electrostatic discharge. A static
ground wrist strap must be worn when handling the circuit
packs. See electrostatic discharge considerations in
Trouble Clearing: TAD-100.
NOTE:
If the DDM-2000 fails to respond in the indicated manner,
refer to Trouble Clearing: IXL-001.
NOTE:
It is assumed the DDM-2000 FiberReach shelves have been
equipped and tested (System Turnup: NTP-007). It is also
assumed that all DDM-2000 OC-3 shelves in the system
have passed the looped transmission test(s) and the
DDM-2000 OC-3/OC-12 ring has been established
( 363-206-285,
DDM-2000
OC-3 Multiplexer, TARP Release
13 and Later, User/Service Manual (TOP) — Volume II
,
System Turnup: NTP-016).
Determine the network configuration (for example, see Figure 1).