NTP-009
: System Turnup 363-206-305
Page 6 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
DLP-535
12.
NOTE:
The rtrv-pm-line command in the following procedure
displays performance monitoring data associated with the
OC-1 lines terminated on the system.
Perform end-to-end OC-1 line test.
13. Repeat this procedure for all OC-1 optical spans being
established in the DDM-2000 OC-3 or OC-12/OC-1 network.
Ensure that the last optical span connected to the OC-3 host shelf
is connected to an
OLIU
in the opposite slot as the one in the first
host OC-3 shelf (for example, slot
2(P)
at one node and slot
1
at
the other node).
14. The dual-homed FiberReach access network is now is ready for
initial service to be established.
Initial DS1 Service [
System Turnup: NTP-004
]
Initial T1 Service [
System Turnup: NTP-013
]
Initial HDSL Service [
System Turnup: NTP-017
]
Initial DS3 Service [
System Turnup: NTP-025
]
STS-3c Service [
System Turnup: NTP-016
]