NTP-013
: System Turnup 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
2.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type and
version information for one or more slots. See the
"Commands and Reports" section of this manual for a
description of the rtrv-eqpt: command format.
At each FiberReach terminating end, use the rtrv-eqpt:
command to obtain the Equipage and Version Report and
verify that the proper service and protection (if required)
T1EXT
circuit packs have been installed in LOW SPEED slot(s) being put
into service.
3. At the T1 terminating node(s) of the circuit being established,
determine which T1 port(s) is to be put into service and what
options are to be selected.
4.
NOTE:
The rtrv-t1: command retrieves the T1 Port
Provisioning Report. This report lists information about
each T1 port. This information includes attributes set by the
set-t1: command. See the "Commands and Reports"
section of this manual for a description of the rtrv-t1:
command format.
At each T1 terminating node, use the rtrv-t1: command to
obtain the T1 Port Provisioning Report and verify the
hardware and software option settings.
5. At each T1 terminating node, use the set-t1: command to set
the characteristics of the T1 port of the circuit being established.
6. At each T1 terminating node, make the appropriate cable
connection(s) to the DS1 interconnect assembly, cross- connect
point(s), or equivalent connection point(s) for the circuit being
added.