NTP-013
: System Turnup 363-206-305
Page 4 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
DLP-510
10.
NOTE:
For a DS1 circuit in a path protected ring network, the
sw-path-( ):address command must be used at the
terminating nodes to switch the active VT1.5 (DS1) path to
repeat this test on the other path(s).
Perform DS1 end-to-end transmission test for each circuit being
put into service, as required.
11. Use the rtrv-state: command to determine the port state of
the DS1 port(s) of the circuit being established.
12.
NOTE:
If a port is in the
nmon (n)
state, the signal is not monitored
or alarmed. The port will not automatically go to the
in
service (i)
state when a signal is detected as it will in the
auto
(a)
state. In the nmon state, the port must be returned to the
auto state, using the set-state-t1: command, to turn on
monitoring of signal failures and before any circuit packs
associated with that port can be removed from the
equipment list by the upd command.
Use the rtrv-state-t1/set-state-t1: command to
verify/set the port state of the T1 port(s) of the circuit being
established.