363-206-305 System Turnup:
NTP-017
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
11.
DLP-510
NOTE:
For a DS1 circuit in a path protected ring network, the
sw-path-( ):address
command must be used at the
terminating nodes [and dual ring interworking (DRI) nodes in
a DRI ring network] to switch the active VT1.5 (DS1) path to
repeat this test on the other path(s).
Perform DS1 end-to-end transmission test for each circuit being
put into service, as required:
A. FiberReach Configurations
B. Dual-Ring Interworking (DRI) Configuration in 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release 13 and Later,
User/Service Manual (TOP) - Volume II,
DLP-554
.
12. Use the
rtrv-state-eqpt:
command to determine the port
state of the DS1 port(s) of the circuit being established.
13.
NOTE:
If a port is in the
nmon (n)
state, the signal is not monitored
or alarmed. The port will not automatically go to the
in
service (i)
state when a signal is detected as it will in the
auto
(a)
state. In the nmon state, the port must be returned to the
auto
state, using the
set-state-t1:
command, to turn on
monitoring of signal failures and before any circuit packs
associated with that port can be removed from the
equipment list by the upd command.
Use the
set-state-t1:
command to set the port state of the
DS1 port(s) of the circuit being established.
14. Use PairGain procedures to access the faceplate RS-232
interface and set HDSL link management features for each port
being provisioned.