NTP-017
: System Turnup 363-206-305
Page 4 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
NOTE:
The following commands may be used to convert, delete,
enter, and retrieve cross-connections: dlt-crs-sts1,
dlt-crs-vt1, ent-crs-sts1, ent-crs-vt1,
rtrv-crs-sts1, and rtrv-crs-vt1. See the
"Commands and Reports" section of this manual for a
description of commands. See "Cross- Connection
Provisioning" in the "Administration and Provisioning"
section of this manual for more information on
cross-connection provisioning.
Determine the necessary cross-connections for each node from
the work order or circuit order.
10. Make necessary VT1.5/STS1 cross-connections at each node in
the network:
DLP-518
A. Single-Ring Configuration
DLP-526
B. Single/Dual OC-3 or OC-12/OC-1 FiberReach Configuration
DLP-528
C. Stand-Alone OC-3/OC-1 FiberReach Configuration
DLP-530
D. Single/Dual OC-48 or OC-192/OC-3 or OC-12 FiberReach
Configuration
DLP-535
E. Single/Dual OC-12/OC-3 FiberReach Configuration
F. Dual-Ring Interworking (DRI) Configuration in 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release 13 and Later,
User/Service Manual (TOP) - Volume II,
DLP-550
.