NTP-024
: Circuit Order 363-206-305
Page 8 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
DLP-514
15. Connect one pair of optical fibers from an adjacent shelf to new
FiberReach shelf
MAIN-1 OLIU
. Ensure that you connect the
fibers correctly [From adjacent OC-3/OC-12 shelf
MAIN 2(P)
OLIU
or FiberReach shelf
MAIN-2 OLIU
to new OC-3/OC-12 shelf
MAIN 1 OLIU
or FiberReach shelf
MAIN-1 OLIU
].
16.
NOTE:
If the report in this step indicates wrong fiber connections or
no connection, verify that
fecom
is ON (rtrv-fecom:) and
check fiber integrity.
Use rtrv-map-neighbor: command to verify proper fiber
connections have been made to the adjacent node.
DLP-514
17. Connect one pair of optical fibers from an adjacent shelf to new
FiberReach shelf
MAIN-2 OLIU
. Ensure that you connect the
fibers correctly [From adjacent OC-3/OC-12 shelf
MAIN 1 OLIU
or
FiberReach
MAIN-1 OLIU
to new OC-3/OC-12 shelf
MAIN 2(P)
OLIU
or FiberReach shelf
MAIN-2 OLIU
shelf.
18.
NOTE:
If the report in this step indicates wrong fiber connections or
no connection, verify that
fecom
is ON (rtrv-fecom:) and
check fiber integrity.
Use rtrv-map-neighbor: command to verify proper fiber
connections have been made to the adjacent node.
19. Verify that all alarm and status conditions clear. If nsa inc. VT
AIS alarm is present and no inc. OC-3/OC-12 LOS alarm,
check that all pass-through cross-connections have been properly
made using the rtrv-crs-vt1: command. If nsa inc. STS
AIS alarm is present and no inc. OC-3/OC-12 LOS alarm,
check that all pass-through cross-connections have been properly
made using the rtrv-crs-sts1: command.