EasyManua.ls Logo

Lucent Technologies FiberReach DDM-2000 - Page 1265

Lucent Technologies FiberReach DDM-2000
1896 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
363-206-305 Circuit Order:
NTP-024
Issue 3, June 2000 Page 9 of 12
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
20. Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne:
command to make new settings.
21.
NOTE:
OC-3/OC-12 shelves with Release 15 and FiberReach
OC-3/OC-12 shelves with Release 4 software support
AGNE(s) and alarm groups. OC-12 shelves with Release 7
or 13 and FiberReach OC-3 shelves with Release 3 software
do not support these features and will not appear in the
alarm groups of a network with mixed software.
NOTE:
The Remote NE Status (rnestat) parameter of the
set-ne: command must be enabled prior to designating
the AGNE(s) and alarm group numbers.
NOTE:
Shelves may be designated as an alarm gateway network
element (AGNE) and assigned an alarm group number.
(Default alarm group number is 255.) At least one AGNE is
required per alarm group. One primary AGNE and one
backup per alarm group is recommmended. For a network
greater than 16 nodes, the AGNE and TL1 GNE should be
on separate nodes. The AGNE parameter of the set-ne:
command may have been set to yes on each new shelf
during shelf turnup procedures to suppress an AGNE
communication failure alarm.
Use the set-ne: command to designate the AGNE(s) and
alarm group numbers, as required.