NTP-024
: Circuit Order 363-206-305
Page 10 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
22.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAP
AREA
field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3 command
be set. See Section 11 “Commands and Reports” in
363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release
13 and Later, User/Service Manual - Volume I
and this
manual, for an explanation of the command parameters and
824-102-144,
Lucent Technologies 2000 Product Family,
Operations Interworking Guide for TARP Releases
, for an
explanation of the engineering rules for subnetworking
partitioning.
Use the ent-ulsdcc-l3 command to designate the NSAP
AREA
field and level 2 IS-IS routing, as required.
DLP-515
23. Perform end-to-end OC-3/OC-12 optical line test on optical spans
being established.
24.
NOTE:
Proper cross-connections must be made at each shelf to
establish the complete end-to-end path for the
DS1/DS3/EC-1 port being tested. After one path (ring1 or
ring2) has been tested, use the sw-path-( ): command
at both ends to test the other ring path.
Perform appropriate end-to-end transmission test for the circuits
being added, as required. Refer to the DDM-2000 OC-3
User/Service Manual (TOP) for the following procedure
DLP-510
A. Single Ring DS1 Test
DLP-511
B. Single Ring DS3 Test
C. Dual Ring Interworking (DRI) DS1 Test in 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release 13 and
Later, User/Service Manual (TOP) - Volume II
,
DLP-554