NTP-025
: System Turnup 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
2.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type and
version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command.
Use rtrv-eqpt: command to obtain the Equipage and
Version Report and verify that the service and protection (if
required) DS3 circuit packs have been installed in the Function
Units slots being put into service.
3.
NOTE:
The rtrv-t3: command retrieves the T3 Port
Provisioning Report. This report lists information about
each DS3 port. This information includes attributes set by
the set-t3: command. See the Commands and Reports
section of this User/Service Manual for a description of the
rtrv-t3: command.
Use the rtrv-t3: command to obtain the T3 Port
Provisioning Report and verify the software option settings.
DLP-513
4. Verify the line build out (LBO) option jumpers are installed as
required and reinstall
DS3
circuit packs.
5. Make the appropriate cable connection(s) to the DS3
cross-connect point(s) or equivalent connection point(s) for the
circuit being added.
6. Verify that no LEDs or alarms are activated. If any LEDs or alarms
are activated, refer to
Trouble Clearing: IXL-001
and follow the
appropriate trouble clearing procedure.
7. If one of the terminating nodes is equipped with
STS1E
or
3STS1E
circuit packs for an EC-1 interface to support DS3
services being established, establish initial EC-1 low speed
interface in 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP
Release 13 and Later, User/Service Manual (TOP) - Volume II
,
NTP-034
or 363-206-295,
DDM-2000 OC-12 Multiplexer, TARP
Release 7, User/Service Manual (TOP) - Volume II
,
NTP-023
.