NTP-025
: System Turnup 363-206-305
Page 6 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
13.
NOTE:
If a port is in the
nmon(n)
state, the signal is not monitored
or alarmed. The port will not automatically go to the
in
service(i)
state when a signal is detected as it will in the
auto(a)
state. In the
nmon
state, the port must be returned
to the
auto
state, using the set-state-t3: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t3: command to set the port state of the
DS3 port of the circuit being established.