363-206-305 System Turnup:
NTP-025
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
10.
NOTE:
For a DS3 circuit in a path protected ring network, the
sw-path-sts1: address command must be used at the
terminating nodes [and dual ring interworking (DRI) nodes in
a DRI ring network] to switch the active STS-1 (DS3) path to
repeat this test on the other path(s).
Perform DS3 end-to-end transmission test for each circuit being
put into service (optional).
DLP-545A. Single-Ring Configuration
DLP-545B. Single/Dual Homing Ring Configuration
C. Dual Ring Interworking (DRI) Configuration in
363-206-285,
DDM-2000 OC-3 Multiplexer, TARP
Release 13 and Later, User/Service Manual (TOP) -
Volume II
, DLP-553
D. Dual Ring Interworking (DRI) Configuration in
363-206-295,
DDM-2000 OC-12 Multiplexer, TARP
Release 7, User/Service Manual (TOP) - Volume II
,
DLP-553
11. Use the set-t3: command to set the characteristics of the DS3
port of the circuit being established.
12. Use the rtrv-state-eqpt: command to determine the port
state of the DS3 port of the circuit being established.
.