NTP-030
: System Turnup 363-206-305
Page 2 of 10 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
Determine the network configuration (for example, see Figure 1.)
DLP-531
2. Verify that the host DDM-2000 host OC-3 shelf is equipped with
TARP Release 15 ring software. If not equipped with TARP
Release 15 software, upgrade the DDM-2000 OC-3 host shelf
with proper software. Verify that the DDM-2000 FiberReach OC-3
shelf is equipped with TARP Release 4 ring software.
3. Determine the optical loss of each optical span from office records
or by making the required measurements.
4.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type
and version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command format.
NOTE:
If work order or office records do not specify
OLIU
types,
refer to 363-206-200,
DDM-2000 OC-3 and OC-12
Multiplexers, Applications, Planning, and Ordering Guide,
363-206-300,
DDM-2000 FiberReach Multiplexer,
Applications, Planning, and Ordering Guide,
363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release 13 and Later,
User/Service Manual—Volume I,
and/or
363-206-305,
FiberReach Multiplexer, Wideband/Narrowband Shelf, TARP
Release 3 and Later, User/Service Manual—Volume I
for a
for a description of
OLIU
circuit packs and applications.
Optical line power measurements and/or office records must
be used to verify that the span length can be supported.
At the host OC-3 node, verify/install
OLIU
circuit packs in
FUNCTION UNITS
slots (
A
,
B
, or
C
) being used for linear
extension OC-3 access.