NTP-033
: Circuit Order 363-206-305
Page 10 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
42.
NOTE:
A CP removed alarm will occur and an inc. OC3 LOS
alarm will occur at the connecting Node when the
MAIN-2
OLIU
is removed from this Node. Other nodes will receive
inc. VT and STS AIS alarms.
At Node 4, remove optical fibers and lift the faceplate latch of
MAIN-2 OLIU
for next span being established, then remove
MAIN-2 OLIU.
43.
NOTE:
When the
29-Type OLIU
is installed an
unexpected CP type status, OLIU CP failed, and
OLIU connector failed alarm will occur. An
inc. OC3 LOF alarm will occur at the Node connected to
this
OLIU
.
Install a
29-Type OLIU
into
MAIN-2 OLIU
slot and reconnect
optical fibers.
44. Connect the OC-12 faceplate connector between
MAIN-1
and
MAIN-2 29-Type OLIU
s. Wait until OLIU connector failed
and OLIU CP failed alarms clear.
45.
!
CAUTION:
The update
(upd)
command must be executed at the Node
with both
29-Type OLIU
s
installed
.
NOTE:
After the update at this node, the inc. OC12 LOF alarm
remains until the
29-Type OLIU
is installed at the connecting
Node.
Momentarily depress the
UPD
button on the
SYSCTL
or execute
the update (upd) command at the Node with both
29-Type OLIU
s
installed.