TAP-102
: Trouble Clearing 363-206-305
Page 10 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
19. If possible, use CIT and rlgn command to log in to the far-end terminal
(
DLP-522
) and use the reset command to reset
SYSCTL
at the far end.
20. Is the
FAULT
LED on the
SYSCTL
circuit pack still flashing (section DCC
channel failed)?
If
YES
, proceed to
Step 25
.
If
NO
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
21.
NOTE:
Unseating and reseating the
SYSCTL
performs a
reset
procedure which
restarts the software program.
Unseat and reseat
SYSCTL
circuit pack. Do not depress
UPD/INIT
button.
22. Is the
FAULT
LED on the affected circuit pack still flashing?
If
YES
, continue with
Step 23.
If
NO
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
23. Obtain a CIT and repeat this procedure.
24.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
25. Refer to
DLP-501
and replace
SYSCTL
at near-end terminal.
26. Is the
FAULT
LED on the
SYSCTL
circuit pack still flashing?
If
YES
, continue with
Step 27
.
If
NO
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
27. At far-end terminal, reset
SYSCTL
by unseating and reseating
SYSCTL
or by
using a CIT and the reset command, if not already performed. If
FAULT
LED
is still flashing after a reset, refer to
DLP-501
and replace
SYSCTL
at far-end
terminal.
28.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
29. Is the
FAULT
LED lighted on the
SYSCTL
?
If
YES
, continue with
Step 30
.
If
NO
, proceed to
Step 37
.