363-206-305 Trouble Clearing:
TAP-102
Issue 3, June 2000 Page 11 of 14
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
30. Use CIT and rtrv-ne command to check provisioning of TID. Two or more
shelves cannot have the same TID.
31. Is provisioning correct?
If YES, proceed to Step 33.
If NO, continue with Step 32.
32. Change provisioning using the set-ne command.
33. Is the FAULT LED still lighted?
If YES, continue with Step 34.
If NO, proceed to Step 36.
34. Refer to DLP-501 and replace the SYSCTL.
35. Is the FAULT LED still lighted on the SYSCTL?
If YES, proceed to Step 37.
If NO, continue with Step 36.
36. Is the MJ alarm LED still lighted?
If YES, continue with Step 37.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
37. The problem appears to be in the backplane of the DDM-2000 FiberReach or
another circuit pack in the shelf is causing the FAULT LED on the SYSCTL to
light. Remove service from shelf and unseat all circuit packs except SYSCTL.
If the trouble clears, it means that one or more of the circuit packs removed is
defective. If the trouble cannot be isolated by removing circuit packs, seek
technical assistance and/or replace the shelf. Notify your supervisor, your
local technical support organization, or call Lucent Technologies RTAC, per
local operating instructions.
38. STOP. YOU HAVE COMPLETED THIS PROCEDURE.