TAP-103
: Trouble Clearing 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
4. Is the
FAULT
LED on the circuit pack just replaced off?
If
YES
, continue with
Step 5
.
If
NO
, do
TAP-106
.
5. Replace the protection circuit pack with the lighted
FAULT
LED.
Reference:
DLP-523
6. Is the
FAULT
LED on the circuit pack just replaced off?
If
YES
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO
, do
TAP-106
.
7. Are the
FAULT
LEDs on two or more service
DS1
,
DS1PM
,
T1EXT
,
HDSL
,
or
DS3
circuit packs lighted (not flashing)?
If
YES
, continue with
Step 8
.
If
NO
, proceed to
Step 12
.
8. Replace either of the service
DS1
,
DS1PM
,
T1EXT
,
HDSL
,
or
DS3
circuit
packs with the lighted
FAULT
LED.
Reference:
DLP-523
9. Is the
FAULT
LED on the circuit pack just replaced off?
If
YES
, continue with
Step 10
.
If
NO
, do
TAP-106
.
10. Replace the other service
DS1
,
DS1PM
,
T1EXT
,
HDSL
,
or
DS3
circuit pack
with the lighted
FAULT
LED.
Reference:
DLP-523
11. Is the
FAULT
LED on the circuit pack just replaced off?
If
YES
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO
, do
TAP-106
.
12. Use CIT and the rtrv-( ) commands (rtrv-state-eqpt, rtrv-sync,
etc.) to check switching mode for inhibits, locks, etc.