TAP-107
: Trouble Clearing 363-206-305
Page 20 of 22 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
protection CP different MN This message will only be seen when a FiberReach
node is configured for 1X7 low-speed protection.
The circuit pack in the protection slot is different
from and will not protect all of the circuit packs in
the service slots. If this is acceptable, execute the
update (upd) command to clear the alarm.
Otherwise, one or more of the service or protection
circuit packs must be changed.
section DCC channel failed MJ or MN The system cannot communicate with the far-end
system through the SONET section data
communications channel (DCC).
Likely cause:
SYSCTL
or
OHCTL
circuit pack
failure, reset, or initialization at the far end, failed
program installation at far end, program installation
in progress at the far end, or
SYSCTL
circuit pack
failure at the near end.
SYSCTL CP failed MJ Internal equipment failure of the
SYSCTL
circuit
pack. The system has determined that some part
of the
SYSCTL
circuit pack has failed.
Note:
Some
types of failures cannot be reported since the
SYSCTL
circuit pack cannot function under these
conditions.
SYSCTL standby boot fail MN
SYSCTL
circuit pack failed during local or remote
software download.
Table B RTRV-ALM Message Descriptions (Continued)
Description
Alarm
Level Meaning