363-206-305 Trouble Clearing:
TAP-107
Issue 3, June 2000 Page 21 of 22
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
unexpected CP switches CR, MJ,
or MN
When associated with the
SYSCTL
slot, this
message means that an invalid switch setting has
been selected or some of the unused switches are
not in the prescribed position. For LOW SPEED
slots equipped with
DS1
,
DS1PM
, or
T1EXT
circuit
packs or FUNCTION UNITS slots equipped with
DS3
circuit packs, this message means that a
change in a circuit pack switch setting was made.
unexpected CP type CR, MJ,
MN, or
Status
When associated with a FUNCTION UNITS slot,
this message means that a different but supported
circuit pack is inserted in a slot already
provisioned. When associated with a LOW SPEED
slot equipped with a
DS1
,
DS1PM
, or
T1EXT
circuit
pack, this message means that a different but
supported
DS1
,
DS1PM
, or
T1EXT
circuit pack
type (for example,
BBF3
circuit pack) is inserted in
a slot already provisioned. When associated with a
MAIN
slot, if a
28-Type OLIU
or
29-Type OLIU
is
inserted into a
MAIN
slot of a FiberReach shelf
expecting a
26-Type
OLIU
, the alarm level for the
resulting unexpected CP type alarm is "status".
If the
28-Type OLIU
or
29-Type OLIU
fails, a OLIU
CP failed alarm is reported; but the status
condition is maintained until the circuit pack is
removed.
X.25 communication failure MJ Failure in the X.25 communication channel.
Likely cause:
Failure of the X.25 communication
equipment or failure at the OS.
Table B – RTRV-ALM Message Descriptions (Continued)
Description
Alarm
Level Meaning