363-206-305 Trouble Clearing:
TAP-112
Issue 3, June 2000 Page 15 of 16
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
36.
NOTE:
If there is a DCC failure, a remote login to the shelf connected through
the Source Address cannot be done. The rtrv-alm,
rtrv-map-network, and rtrv-map-neighbor commands can be
used to check for dcc failure for main. Also, use rtrv-fecom command
to see if "fecom" has been disabled.
Note Source Address of DCC channel failure. Check optical fibers
connected through the Source Address per local procedures. If no trouble
found, replace near-end OLIU first then far-end OLIU.
Reference: DLP-523
37. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
38. Use CIT and reset command to reset SYSCTL at the near end or unplug and
reseat the SYSCTL.
39. Is the FAULT LED on the SYSCTL circuit pack still flashing (section DCC
channel failed)?
If YES, continue with Step 40.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
40. If possible, use CIT and rlgn command to log in to the far- end terminal
(DLP-522) and use the reset command to reset SYSCTL at the far end.
41. Is the FAULT LED on the SYSCTL circuit pack still flashing (section DCC
channel failed)?
If YES, continue with Step 42.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
42.
NOTE:
You may prefer to go to the far end first and check if the SYSCTL is failed
or removed before replacing the SYSCTL at the near end.
Refer to DLP-501 and replace SYSCTL at near-end terminal.
43. Is the FAULT LED on the SYSCTL circuit pack still flashing?
If YES, continue with Step 44.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.