363-206-305 Trouble Clearing:
TAP-116
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
17. Unseat and reseat SYSCTL to perform reset.
18. Is alarm still present?
If YES, continue with Step 19.
If NO, proceed to Step 21.
19. Has SYSCTL been replaced?
If NO, continue with Step 20.
If YES, proceed to Step 23.
20. !
CAUTION:
Replacing the
SYSCTL
involves updating the internal memory on the
circuit pack.
Replace the SYSCTL.
Reference: DLP-523
21. Repeat program installation procedure.
Reference: DLP-536
22. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
23. If you need technical assistance, notify your supervisor, your local technical
support organization, or call Lucent Technologies RTAC, per local operating
instructions.
24. STOP. YOU HAVE COMPLETED THIS PROCEDURE.