TAP-116
: Trouble Clearing 363-206-305
Page 4 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
15.
NOTE:
The new program installation may have failed because of faulty diskettes.
Disconnect PC and repeat program installation procedure. Use your
backup
diskettes
containing new generic program, if available. If new program
installation cannot be completed and the old program has been erased, one
the following procedures may be used to restore the old program or install a
different version program.
A. If a "
P.
" was displayed in the
FE ID
display during a software download,
indications are that a portion of the program has been erased and you will
have to reinstall the program. You may be able to use the ins-prog:tid
or cpy-prog:tid command from a far-end shelf to reload software. Go
to the far-end shelf and establish session with a CIT. Enter the
ins-prog:tid or cpy-prog:tid command where the tid is the tid
(shelf name) for the failed shelf where you want to install the old program.
B. If a "
P.
" was displayed in the
FE ID
display during a software download
and you cannot load the program from the far-end, you can force the
download. To load another version of software, unseat and then reseat the
SYSCTL
and immediately push and hold the
FE SEL
and
UPD/INIT
buttons at the same time until a "
P
" appears in the
FE ID
display. Release
buttons and repeat the download procedure.
C. Replace the
SYSCTL
with ones that have compatible software. [
DLP-523
]
D. If a "
C
" was displayed in the
FE ID
display after a software download,
indications are that the software loaded will not support the current
system transmission configuration. This indicates a problem with the
version of software you are trying to install, or you are trying to install a
version of software that does not support the system configuration that
you have. To load another version of software, unseat and then reseat the
SYSCTL
and immediately push and hold the
FE SEL
and
UPD/INIT
buttons at the same time until a "
P
" appears in the
FE ID
display. Release
buttons and repeat the download procedure.
If you need technical assistance, notify your supervisor, your local technical
support organization, or call Lucent Technologies RTAC, per local operating
instructions.
16.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.