363-206-305 Trouble Clearing:
Issue 3, June 2000 Page 1 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
TAP-117
Clear NE ACTY Alarm Only
1. Connect the CIT to the CIT connector on the near-end User Panel and log in to
the near-end system.
Reference: DLP-521
2.
NOTE:
The rtrv-alm command can be used to display a report of active alarm
and status conditions. The Commands and Reports section in Volume I
of this manual gives a description of the command.
NOTE:
The Active Alarm and Status Report is output automatically
following CIT log in. The report shown in Figure 1 is an example that
shows one entry. There may be many entries in the actual report.
Note the information in the Source Address and Description columns for
the top entry/entries above the first single-dashed line in the Active Alarm
and Status Report (Figure 1) (for example, “ne-acty m2-1-1-1 MM-DD
HH:MM:SS nsa inc. VT AIS”).
Figure 1 – Example of Active Alarms and Status Report
*Active Alarms and Status Report
===============================================================
Alarm Source Date Time Srv Description
Level Address Detected
===============================================================
ne-acty m2-1-1-1 MM-DD HH:MM:SS nsa inc. VT AIS
---------------------------------------------------------------
*/