TAP-117
: Trouble Clearing 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
3.
NOTE:
Local alarm or status conditions have a Source Address of the local slot,
line, port, channel, path, cross-connection, or operations interface (DCC,
CIT, X.25, etc.) where the event occurred. (See
Addresses
in the
Commands and Reports section of this manual.) Use the rtrv-alm
command to get another report, if necessary.
Note the trouble indication in the Description column of the Active
Alarm and Status Report.
4. Find the trouble description in Table A and perform the indicated repair
procedure(s).
5.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.