363-206-305 Detailed Level Procedure:
DLP-500
Issue 3, June 2000 Page 7 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
17.
NOTE:
After the prompt ( < ), the system will respond to commands entered.
The set-link:pg=( ) command may be used to set the vertical size
of the displayed page on the CIT. Page (pg) length may be set from 3 to
150 lines with a default length of 24 lines.
NOTE:
There are four types of users:
Privileged
users may execute any command, including restricted
commands.
General
users may execute any commands that are not restricted to
privileged users.
Maintenance
users may execute commands that obtain nonprivileged
system reports, perform protection switching, loopback activities, and
perform some other maintenance activities.
Reports-only
users may only execute commands that obtain
nonprivileged system reports.
Refer to
Security
in the "Administration and Provisioning" section of this
manual for more information about restricted commands.
NOTE:
Three privileged and up to 100 nonprivileged (general and/or
reports-only) logins are supported. If a user attempts to enter another
login when the maximum supported logins already exist, the command
will be denied.
NOTE:
The three privileged user logins may be edited to change the login name
and/or password, but privileged user logins cannot be added or deleted.
See the "Commands and Reports" section of this manual for a
description of the set-lgn: command format.
Use the set-lgn: command to edit, delete, or enter logins/passwords and
user types, as required.