DLP-501
: Detailed Level Procedure 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
4. Set
SYSCTL
switch sections
S2-1
and
S2-2
to
OFF
and switch sections
S2-3
,
S2-4
,
S2-5
,
S2-6
,
S2-7
, and
S2-8
to
ON
.
Figure 1. SYSCTL Option Settings
5.
NOTE:
Steps 6 and 7 must be performed without unnecessary delays.
Familiarize yourself with these steps before continuing with the
procedure.
Read Steps 6 and 7 before proceeding.
6.
!
!
CAUTION:
Take care to avoid damaging the LEDs that protrude through the opening
in the faceplate of the
SYSCTL
.
!
CAUTION:
Initializing the
SYSCTL
in the following steps will momentarily interrupt
service if protection switches are activated.