363-206-305 Detailed Level Procedure:
DLP-501
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
9. Find SYSCTL with compatible software and repeat this procedure, or install
new software using the procedures of DLP-525.
10. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
11. If FiberReach compatible software is installed, you can retrieve the generic
software version ID by depressing the ACO button longer than 2 seconds and
observing version code on the FE ID display. If the software version is not the
correct version, you must find a SYSCTL with the correct software or install
new software using the procedures of DLP-536.
If software not compatible with the FiberReach shelf is installed in the SYSCTL
and you cannot retrieve the software version (no response), you must find a
SYSCTL with the correct software or install new software using the procedures
of DLP-536.
12.
NOTE:
If you are using this procedure to replace a SYSCTL that was already in
service and the correct version of software is installed, there may have
been some options set using the craft interface termainal (CIT).
Refer to DLP-512 and set any required options.
13. STOP. YOU HAVE COMPLETED THIS PROCEDURE.