363-206-305 Detailed Level Procedure:
DLP-537
Issue 3, June 2000 Page 1 of 10
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Install New Software Generic Program
Network Element Software
Remote Shelf Download
In-Service System
1. Before beginning the software installation, refer to the Software Installation
and Upgrade Procedure section of the Software Release Description. This
section contains a description of any special considerations required when
installing this version of software.
2.
NOTE:
This procedure uses the cpy-prog: or ins-prog: commands to install
a new software program in a remote in-service DDM-2000 FiberReach
shelf. It is assumed that the local shelf has already been upgraded and
the software is running normally or has been installed as a dormant copy.
For procedures to download software in a new shelf (initial installation),
see DLP-525. For procedures to download software locally to a shelf, see
DLP-536.
NOTE:
If upgrading from earlier software releases to TARP Release 3.0 and
later, after the first shelf is upgraded, single-ended operations will not be
available and major alarms (section DCC channel failed) will exist
until all shelves are upgraded. The node farthest away should be
upgraded first, working back to the local node. See 824-102-144,
Lucent
Technologies 2000 Product Family, Operations Interworking Guide For
TARP Releases
, for guidelines in subnetwork upgrade procedures.