EasyManua.ls Logo

Lucent Technologies FiberReach DDM-2000 - Page 1726

Lucent Technologies FiberReach DDM-2000
1896 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DLP-536
: Detailed Level Procedure 363-206-305
Page 14 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
35. Execute the apply: command at the shelf to receive the software.
Response: A "
P
" appears in the
FE ID
display when the installation
begins.
The
SYSCTL
resets after the software is installed.
LEDs and
FE ID
display go off on
SYSCTL
and User
Panel.
You are logged off the system.
After approximately 5 minutes you can log back into the
shelf and reestablish communications.
36. Was response correct?
If
YES
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
If
NO
, continue with
Step 37
.
37. Did the letter "
C
" appear in the
FE ID
display?
If
NO
, do
Trouble Clearing: TAP-116
.
If
YES
, proceed to
Step 22
.

Table of Contents