DLP-537
: Detailed Level Procedure 363-206-305
Page 4 of 10 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
6. Are you using ins-prog: or cpy-prog: command to download software to
far-end shelf?
If
CPY-PROG
, continue with
Step 7
.
If
INS-PROG
, proceed to
Step 14
.
7.
!
CAUTION:
Only one
cpy-prog:
procedure at a time should be performed in the
same maintenance subnetwork. Simultaneous
cpy-prog:
procedures
in the same network may fail.
Connect and establish session with local shelf being used as a source for the
new remote program download.
Reference:
DLP-521
8. Enter the command cpy-prog:tid.
Where tid = the target identifier (shelf name) for the remote
DDM-2000 shelf receiving the new program.
Where pgmtype = the type of software you want to install.
Response: /* Testing For Program Installation... */
After several seconds, the PC prints a Caution!
message followed by the prompt:
Execute? y/n =
9. Was response correct?
If
YES
, continue with
Step 10
.
If
NO
, do
Trouble Clearing: TAP-116
.