363-206-305 Detailed Level Procedure:
DLP-537
Issue 3, June 2000 Page 5 of 10
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
10. Enter a
y
or
yes
and a carriage return to execute the program. Software
download may take up to 20 minutes.
Response: ABN LED lights on User Panel. A "P. " is displayed in
SYSCTL FE ID display in the far-end shelf receiving the
program (for uncompressed executing copy download, not
if dormant copy is being loaded). At DDM-2000 shelves
connected directly to the shelf receiving the program, MJ
and NE ACTY LEDs light on User Panel. At other shelves
in the same control system, MJ and FE ACTY LEDs light
on User Panel. Download begins and the following
message is displayed:
In progress . . . .
The dots continue to print until program installation is
complete. After installation is completed, the PC prints the
following completion message:
ins-prog:
TID
COMPLD
/* Generic a.b.c is installed */
The LEDs go off on the User Panel and SYSCTL.
11. Was response correct?
If YES, proceed to Step 27.
If NO, continue with Step 12.
12. Wait approximately 5 minutes for network to stabilize then repeat this
procedure from Step 7. If the second attempt to download software fails, then
do Trouble Clearing: TAP-116. You may have to go to the remote site.
13. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
14.
NOTE:
The FE ID display on the remote SYSCTL must show one of the following
preceding software installation. Other conditions represent failure
conditions or conditions that will not allow a remote software download.
A. The letter "P. " displayed in the FE ID display indicates corrupted
application software and you may be able to download software from
another shelf, or locally. Try again to download software from same
shelf. If there is no period after the "P", the software can only be
downloaded locally using the procedures of DLP-536.