DLP-537
: Detailed Level Procedure 363-206-305
Page 6 of 10 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
B. Nothing displayed in the
FE ID
display indicates that compatible soft-
ware is installed in the
SYSCTL
and you may download software
remotely if remote software downloading is permitted for this release.
Ensure PC is connected to the front CIT (CIT-1). If floppies are being used,
ensure the first (number 1) diskette is installed in floppy drive. If hard drive is
being used, ensure you are in the correct directory.
15. Enter term or term COM
n
command, where
n
= 1 or 2. If term is entered
without the COM
n
option, then
COM1
will be selected by default. If after starting
the terminal emulator you see the message Can’t find script <init>,
disregard it.
Response: Two brief messages are printed and you are instructed to
Press any key to continue . . . after the
second message. After you press any key, the terminal
emulator is loaded and the terminal responds as follows:
CTRM ready. (Type Alt-h for help.)
Communications established.
16.
NOTE:
The default shelf is the shelf physically connected to the PC. To set baud
rate automatically, enter two carriage returns (
<cr>
), two lower case "a"s
(
aa
), or two upper case "A"s (
AA
). All other characters are ignored.
Enter two carriage returns.
Response: PC prompts with:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
17. Was response correct?
If
YES
, proceed to
Step 19
.
If
NO
, continue with
Step 18
.
18. Check PC to
CIT
port connections. Make sure the cable is connected between
the PC
COM( )
port and the
CIT
connector on the DDM-2000. Check term
setup and make sure the
com
port selected matches the port (
COM( )
) on the
PC that is connected to the
CIT
port on the shelf.
Exit term (Alt-F2) and repeat this procedure from
Step 14
.