DLP-545
: Detailed Level Procedure 363-206-305
Page 6 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
22.
NOTE:
The DS3 test set is used at the end equipped with
DS3
circuit packs
At the cross-connection associated with the near-end DDM-2000, connect the
DS3 test set to the
IN
and
OUT
jacks associated with the circuit under test.
23. Use the DS3 test set to test for error-free transmission.
24. Was the test successful (error free)?
If
YES
, continue with
Step 25
If
NO
, proceed to
Step 34
.
25. Is this the first service being placed on the group and is protection circuit pack
installed?
If
YES
, continue with
Step 26
.
If
NO
, proceed to
Step 29
.
26. Unseat the service
DS3
circuit pack associated with the circuit under test.
27. Repeat the DS3 transmission test with the DS3 test set.
28. Was the test successful (error free)?
If
YES
, continue with
Step 29
.
If
NO
, proceed to
Step 34
.
29. Reseat the
DS3
circuit pack associated with the circuit under test.
30. The DS3 circuit under test has passed the DS3 transmission test. Remove the
looping patch cords from the cross-connections.
31. At the near-end (and the far-end) DDM-2000, momentarily depress the
UPD/INIT
pushbutton on the
SYSCTL
(or use the upd command) to update
the
SYSCTL
.
32. Repeat this procedure from
Step 21
for any additional DS3 circuits to be
tested.
33.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.