363-206-305 Detailed Level Procedure:
DLP-545
Issue 3, June 2000 Page 7 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
34. Has the DS3 circuit pack that failed been replaced?
If YES, proceed to Step 37.
If NO, continue with Step 35.
35. Replace the DS3 circuit pack that failed the test.
Reference: DLP-523
36. Repeat this procedure for the DS3 circuit pack that failed.
37. Trouble may be in the DSX cross-connect, STS1 cross-connections in the
network, or the shelf backplane. Use the rtrv-crs-( ) command to
ensure proper STS1 cross-connections have been made at each shelf in the
ring for the DS3 being tested. If no trouble found, check DSX cross-connect
and backplane connections. If other alarms or trouble indications are present,
refer to Trouble Clearing: IXL-001 to isolate the trouble. If no alarms or
indications are present and a CIT is available, use the RETRIEVE commands
(for example, rtrv-alm, rtrv-hsty, etc.) to check for other trouble
indications.
38. STOP. YOU HAVE COMPLETED THIS PROCEDURE.