DLP-546
: Detailed Level Procedures 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Figure 1 – BBG4/BBG4B/BBG19 DS3 LBO Settings
4. Are your installing
BBG4/BBG4B DS3
or
BBG19 DS3
circuit packs.?
If
BBG4/BBG4B
, continue with
Step 5
.
If
BBG19
, proceed to
Step 8
.
5.
NOTE:
If the response is not correct in the following procedures, replace the
DS3
circuit pack.
Seat a
DS3
circuit pack in Function Units Group slot
FN-1
.
Response:
FAULT
LED on the
DS3
circuit pack lights for about 20 seconds
then goes off.
ACTIVE
LED lights on the first
DS3
circuit pack of
the pair installed.