NTP-004
: Circuit Order 363-206-305
Page 2 of 2 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
Add Channel Units
To add additional service to an existing NBS, the appropriate channel unit(s) must be
installed in the NBS, provisioning must be done at the HDT site, and end-to-end
testing performed. Channel units may be added without interrupting existing service.
Channel Unit Installation and Testing Procedures
DLP-504
1. Install Channel Units
2.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.