363-206-305 Trouble Clearing:
TAP-101
Issue 3, June 2000 Page 3 of 10
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
4.
NOTE:
Verify that the DSX option switch on the server is set appropriately.
Refer to Table A for the
SLC
-2000 HDT user interface panel (UIP) alarm and
fault messages associated with FITL distribution. Refer to Table B for the
SLC
-2000 UIP alarm and fault messages associated with LED indicators at
the
SLC
-2000 HDT and the DDM-2000 NBS. To view alarm or fault messages,
press the UIP Escape button. Then press the Scroll Menu down arrow until
RETRIEVE-ALARMS:
<ent> or RETRIEVE-FAULTS: <ent> is displayed.
Then press Scroll Menu down arrow to scroll through the messages.
Ta bl e A –
SLC
-2000 UIP Alarm and Fault Messages Associated with FITL
Distribution Mode (Notes)
UIP Alarm
Messages
Severity Message Meaning
MJ or MN {aid} rcvd FITL YEL Yellow alarm received from NBS
MN {aid} rcvd MISC MISC alarm received from NBS
MN {aid} DT CU failed CU failed at NBS (Note 1)
MN {aid} ISDN slot err ISDN CU placement violation in NBS (Note 2)
MN {aid} power alarm Power source failure (Note 3)
ABN {aid} dnld abort
DSXBIU
software download/installation failed
ABN {aid} downloading
DSXBIU
software downloading/installation in progress
MN {aid} batt chrg fail DT battery charger failed
MN {aid} isdn cnflt NBS ISDN CU placement violation (Note 4)
UIP Fault
Messages
Severity Message Meaning
MJ or MN {aid} biu failed
DSXBIU
circuit pack failed
MJ or MN, NE {aid} DT CLF RT-to-NBS carrier-line-failure
MN {aid} datalink fail RT-to-NBS ESF datalink failed
MN {aid} cu failed CU failed in NBS
MN {aid} door open DT door(s) open
MJ or MN {aid} rgu failed DT ringing generator failed
MN {aid} pcu failed DT power converter unit failed
MN {aid} cdtu failed DT channel & drop-test unit failed
MN, NE {aid} config DT Server configuration error
MJ or MN, NE {aid} failed DT Server failed
MN {aid} incompat Incompatible CU in NBS
MN {aid} rcvd misc MISC alarm received from NBS
See Notes at end of table