TAP-101
: Trouble Clearing 363-206-305
Page 4 of 10 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
Notes:
• The general syntax of UIP messages: Alarm-severity: which end: AID message.
• Each error message will print a circuit pack address identifier {aid}. For FITL error messages, the
AID will generally begin with the characters 'dt', with the exception of errors involving the DT
Server, which may begin with 'cu' (referencing the MDS CU slot holding the server).
• Note that the DT Server's DT LED will also light when the error is reported by the NBS.
• The NE Activity is indicated where the cause of the message calls for corrective action starting at
the RT.
• In the following notes, the
SLC
-2000 FITL system enhanced alarm reporting is when the
SLC
-2000 HDT, DT Server and the NBS
DSXBIU
operation supports the enhanced alarms.
1. The {aid} reported is of the associated DT Server if the
SLC
-2000 FITL system operation
does not support enhanced alarms. See the
SLC-2000 HDT Software Release 4
Required Circuit Packs for Specific DT Features
table in Chapter 3.
2. This message is displayed whenever NBS reports ISDN channel unit placement
violation.
3. This message is displayed in those versions of the DDM-2000 NBS that do not support
enhanced alarms.
4. This message is displayed whenever
SLC
-2000 HDT determines ISDN channel unit
placement violation at the NBS.