363-206-305 Trouble Clearing:
TAP-101
Issue 3, June 2000 Page 5 of 10
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
Ta bl e B SLC-2000 UIP Alarm and Fault Messages Associated with FITL
Distribution Mode (Notes)
UIP Alarm Messages
Severity Message
LED Indicators
SLC-2000 HDT NBS (DSXBIU)
MJ or MN {aid} rcvd FITL YEL Server — DT
MN {aid} rcvd MISC Server — DT Ne
MN {aid} DT CU failed Server — DT Ne
MN {aid} ISDN slot err Ne/Config
MN {aid} power alarm Server — DT Ne
ABN {aid} dnld abort
ABN {aid} downloading Server — DT (Flashing) All LEDs Flashing
MN {aid} isdn cnflt MDC — Incomp,
Server DT/Config
NC/Config
UIP Fault Messages
Severity Message
LED Indicators
SLC-2000 HDT NBS (DSXBIU)
MJ or MN {aid} biu failed Server — DT FAIL
MJ or MN, NE {aid} DT CLF Server — CLF
MN {aid} datalink fail Server — DT CLF/Fe
MN {aid} cu failed Slot Alloc
(Flashing)/Fe
MN {aid} door open Server — DT
MJ or MN {aid} rgu failed Server — DT Ne
MN {aid} pcu failed Server — DT Ne
MN {aid} cdtu failed Server — DT Ne
MN, NE {aid} config MDC — incomp CLF
MJ or MN, NE {aid} failed MDC — fail CLF
MN {aid} incompat MDC — incomp,
Server — DT/config
Ne/config
MN {aid} rcvd misc Server — DT Ne
The
CONFIG
lamp on
DSXBIU
will flash on download.