DLP-508
: Detailed Level Procedures 363-206-305
Page 4 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
The following is a list of DT Server alarm indicators:
1. The
SPQ
810
/
811
DT Server (Figure 3) is being connected to a NBS.
2. Set the
OU/DSX
option to
DSX
(toward gold fingers).
3. Set the
B/Z
option to
B
option only.
4. Set the DSX equalization
TRANS-0,1,2
options as required (see Table A).
5. Refer to
DLP-616
in 363-208-001,
SLC-2000 Access System User/Service
Manual
for details on further provisioning and installation of the DT server.
6.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
FAIL
The DT Server pack has failed self-diagnostic tests.
CLF
Communication with the NBS is lost.
DT
Trouble with equipment in the NBS.
CONFIG
Placement of a channel unit in the wrong slot or an error
in the SLOT ALLOCATION option setting on the DT
Server channel unit. Correct placement or SLOT
ALLOCATION option setting to clear
CONFIG
alarm. If
the DT Server is installed per work order, record the
digroup channel unit equipage and refer the trouble to
the engineering center. If
CONFIG
and
DT
are both on,
the channel unit installation trouble is at the NBS.