363-206-305 Detailed Level Procedures:
DLP-508
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
Figure 3 SPQ810/811 Option Switches
Table A Equalization Option Settings
Trans-2 1 0
Distance
toDSX-1
(Feet) (Note)
OFF OFF ON 0 to 132
OFF ON OFF 133 to 265
OFF ON ON 266 to 398
ON OFF OFF 399 to 532
ON OFF ON 533 to 655
Note:
These distances are for ABAM cable used in the central
office. Refer to document 915-710-115 for calculations for other
types of cable used for collocated RT and T1 extension
applications.
FAIL
CLF
LUCENT
SPQ808
DT
CONFIG
CU
MJ=
12
MJ=
ANY
ON
2
B
Z
DSXOU
1
TRANS
0
Fiber/T1 carrier
application switch
Equilization
option
Alarm severity
setting jumper
B8ZS/ZCS
option
tpa853935-01