363-206-305
Commands and Reports
Issue 3 June 2000
11-3
Addresses
11
Table 11-1 specifies the valid addresses for slots, lines, ports, channels, paths,
cross-connections, and operations interfaces. Where lists of items appear in
braces { }, and one (and only one) of these items may be used to form the
address.
Each address is made up of several components that are combined to indicate a
specific location on the DDM-2000. The following list shows the potential values
for each address component. Refer to this list when reviewing Table 11-1:
slot type: Possible values are: main, m, fn, ls, sysctl, userpanel,
and all.
group: Possible values are: m, a, b, c, and all.
Note carefully in Table 11-1 when this value is followed by a dash (-)
and when it is not.
slot within a group (abbreviated as slot):
Possible values are: 1-2, and all.
line: Possible values are: 1, 2, and all.
Note carefully in Table 11-1 when all is not allowed.
STS-1: Possible values are: 1-12, and all.
VTG: Possible values are: 1-7, and all.
VT1.5: Possible values are: 1-4, and all.
special: Possible values are: cit, dcc, env, and cont.
environmental alarm or control point (abbreviated as alm/cont point):
Possible values are: 1-15, and all.