7
SC100/200 Series Users Manual EM-6337-B Rev.15
1. BEFORE USE ....
Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives.
This product is for use in general industrial environments, therefore may not be suitable for applications which require higher
level of safety (e.g. safety or accident prevention systems) or of reliability (e.g. vehicle control or combustion control systems).
For safety, installation and maintenance of this product must be conducted by qualied personnel.
PACKAGE INCLUDES:
• Multi-function PID controller.............................................................. (1)
• Resistor module ................................................................................ (2)
• CJC sensor ....................................................................................... (2)
• Mounting bracket .............................................................................. (2)
• Connector adapter
(with stereo jack type)
......................................... (1)
MODEL NO.
Conrm Model No. marking on the product to be exactly what you ordered.
USERS MANUAL
This manual describes detailed operations and necessary points of caution when you use this product, including installation,
connection and basic maintenance procedures.
The SC100/200 Series products are referred to as ‘the Controller’ in this manual if not explained otherwise. The ‘SC’ means
any model of the SC100/200 Series products. Descriptions applicable to specic models are either mentioned with the par-
ticular model numbers, or identied with symbols such as:
The following document will also provide helpful information when using this product:
• SC100/200 Series Function Block List (EM-6460-B)
POINTS OF CAUTION
Conformity with EU directives
• This equipment is suitable for Pollution Degree 2, Installation Category II (transient voltage 2500V) and Measurement Cat-
egory II (contact output, transient voltage 2500V). Reinforced insulation (signal input or output to power input: 300V) and
basic insulation (signal input or output to contact output: 300V) are maintained. Prior to installation, check that the insula-
tion class of this unit satises the system requirements.
• Altitude up to 2000 meters.
• FG (Functional Ground) shall not share with PE (Protective Earth) of other equipment. Ground the FG terminal solely for
signals.
• The equipment must be installed such that appropriate clearance and creepage distances are maintained to conform to CE
requirements. Failure to observe these requirements may invalidate the CE conformance.
• The actual installation environments such as panel congurations, connected devices, connected wires, may affect the pro-
tection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard
to the whole system and employ additional protective measures to ensure the CE conformity.
• In order to enable the operator to turn off the power input immediately, install a switch or a circuit breaker according to the
relevant requirements in IEC 60947-2 and properly indicate it.
• The equipment is intended to be installed in a industrial environment dened by EN 61000-6-2, EN 61000-6-4.
• Analog signals may have some uctuation within ±5 % during following tests:
- EN 61000-4-3: Radiated, radio-frequency, electromagnetic eld
- EN 61000-4-6: Immunity to conducted disturbances, induced by radio frequency elds
- EN 61000-4-8: Power frequency magnetic eld