4-32
4. Remove three 1/4” hex head screws from
inside the blower housing securing it to the
motor bracket.
5. Remove the blower housing
BLOWER HOUSING
1. Remove blower wheel (See page 4-22).
2. Remove wire connectors from thermistor
and thermal fuse (See page 4-31).
3. Remove the short 1/4” hex head screw
securing blower housing to exhaust duct.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Three 1/4” Hex
Head Screws
1/4” Hex
Head Screw
Four Wire