McHale Fusion 2 troubleshooting section
14-3
McHale Fusion 2 round baler wrapper technical service manual
Issue 1: 0208
14.6 Chamber losing pressure
14.7 Machine making soft bales
Reason Solution Reference Section
Oil Leak Find Leak and resolve
Seals gone in the door
ram
Test both rams and
identify leaking ram and
replace seals
Eliminate each ram
individually.
Copper Washer inside
the door cartridge in
door valve leaking
Remove cartridge and
replace copper washer
12.7.3
Bale density valve Replace bale density
valve
12.7
Reason Solution Reference Section
Density set too low for
crop conditions
Increase the density 9.9 Check first
12.7 Second check
Crop build up under the
chamber full sensor
Clean loose crop from
around the door sensor
Faulty accumulator
density needle increase
is not consistent in its
increase as the bale is
being finished
Replace the chamber
accumulator
12.7.4