EasyManuals Logo

Microsens MS400870M Series User Manual

Microsens MS400870M Series
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38
lower active MD-level on the port.
None: No MHFs can be created for this VID.
For example:
Console(config-cfm-assoc)#add myassoc 1 4
none
delete <assoc_name>
To delete a registered association name.
For example:
Console(config-cfm-assoc)#delete myassoc
Console(config-
cfm)#
loopback <target mepid |
mac_address>[-n number(2-100)]
[-s size(1-255)] [-p priority(0-7)]
[-d drop_eligible(true | false)]
To configure loopback test settings.
For Example:
Console(cfm)#loopback domain assoc
00:01:02:03:04:05 -n 100 -s 255 -p 3 -d true
linktrace <target mepid |
mac_address> [-f flag(fdbonly |
none)][-h hop_count(1-255)]
To configure linktrace settings.
For Example:
Console(cfm)# linktrace domain assoc
00:01:02:03:04:05 -f none -h 100
de-measure <target mepid |
mac_address> [-n number(2-100)]
[-p priority(0-7)]
To configure delay measurement settings.
For Example:
Console(cfm)#de-measure domain assoc
00:01:02:03:04:05 -n 100 -p 0
2.6.3 Dot1x command mode
Prompt
Command & Parameter
Description
Console(config-
dot1x-sys)#
mode <enable | disable>
To enable or disable 802.1X for the Managed
Switch.
server <ip_addr>
RADIUS Authentication server address.
secret <shared_secret>
The identification word or number assigned to
each RADIUS authentication server with
which the client shares a secret.
<shared_secret>: up to 30 characters
reauth <enable | disable>
To enable or disable Reauthentication.
period <reauth_period>
The time interval that the system sends out
periodic reauthentication message.
<reauth_period>: 0~3600 Seconds
eap-timeout <eapol_timeout>
The time that the Managed Switch waits for
responses from the server host to an
authentication request.
<eapol_timeout>: 1~255 Seconds
Console(config-
dot1x)#
state <port_list> <auto | authorized
| unauthorized>
Specify each port‟s authentication statue.
<auto | authorized | unauthorized>:
Authorized: This forces the port to grant
access to all clients, either dot1x-aware or
otherwise. “Authorized” is the default setting.
Unauthorized: This forces the port to deny
access to all clients, either dot1x-aware or
otherwise.

Table of Contents