146
Baud rate and so on
are set correctly.
Setting of
command/data is
correct.
Flow control is
specified at host.
13
Setting is correct
By referring to the paragraph 9−3, connect with
Host properly.
By referring to the paragraph 9−3, apply
command/data properly.
Set the following items properly according to the
specifications for below.
FUNC−30 Selection of Baud rate.
FUNC−31 Setting data bit length and parity.
FUNC−32 Setting stop bit.
(Refer to the section 8. Function Mode and the
paragraph 9−3. Options)
Change Yes to No for the flow control at host.
Intended values
are not transmitted in the
Stream mode.
Select the output target in the Stream Mode.
FUNC−28 Selection of output target in
Stream Mode.
(Refer to the section 8. Function Mode and the
paragraph 9−3. RS−232C Interface.)
Inform Minebea about the contents of
failure and situation at site in details.
NO
YES
YES
YES
YES
YES
NO
NO
NO