79
FUNC−14 Setting data width for comparator hysteresis
Initial value = 000000 000000 = Hysteresis data width OFF
Setting range : 000000 000099
Unit : 1 D
99 D data width at “000099” setting
FUNC−15 Setting time width for comparator hysteresis
Initial value = 000000 000000 = Hysteresis time width OFF
Setting range : 000000 000099
Unit : 0.1 second
9.9 second time width at “000099” setting
FUNC−16 Setting target for analog output(Effective when option is installed.)
Initial value = 000002 000000 = Display
000001 = Net weight
000002 = Gross weight
When “Display” is selected, analog output interlocks with display.
When “Net weight” is selected, analog output interlocks with “Net weight” at the
time of executing Tare and interlocks with “Gross weight” at the time of cancellation
of Tare is executed.
On the other hand, when “Gross weight” is selected, analog output interlocks “Gross
weight” value, whichever Tare is executed or not.
FUNC−17 Display value at the time of minimum value of analog output.
(Effective when option is installed.)
Initial value = 000000 Setting range : −099990 099990
FUNC−18 Display value at the time of maximum value of analog output
(Effective when option is installed)
Initial value = 000000 Setting range : −099990 099990
FUNC−19 Changeover of effective/ineffective of A−SEL input signal for
external control. (Effective when option is installed)
Initial value = 002000 000000 = A−SEL ineffective
000001 = A−SEL effective
FUNC−20 Selection of target for BCD output.(Effective when option is installed.)
Initial value = 000002 000000 = Display
000001 = Net weight
000002 = Gross weight
000003 = External selection
When “Display” is selected, BCD output interlocks with display.
When “Net weight” is selected, BCD output interlocks with “Net weight” value at the
time of Tare is executed and also interlocks with “Gross Weight” value at the time of
Tare is cancelled.
When “Gross weight” is selected, BCD output interlocks “Gross weight” value,
whichever Tare is executed or not.
And when “External selection” is selected, the target for BCD output can be selected
among “Display”, “Net weight” and “Gross weight” through the input of SEL1 and
SEL2 on optional “BCD output”.