81
・ FUNC−30 Selection of baud rate for RS−232C and RS−422
(Effective when option is installed.)
Initial value = 000000 000000 = 600 bps
000001 = 1 200 bps
000002 = 2 400 bps
000003 = 4 800 bps
000004 = 9 600 bps
000005 = 19 200 bps
・ FUNC−31 Setting data bit length for RS−232C and RS−422 and parity.
(Effective when option is installed.)
Initial value = 000021 10
0
digit : Data bit length
0 = 8 bits
1 = 7 bits
10
1
digit : Parity set
0 = Non
1 = Even
2 = Odd
・ FUNC−32 Setting stop−bit for RS−232C and RS−422
(Effective when option is installed.)
Initial value = 000000 000000 = 1 bit
000001 = 2 bits
・ FUNC−33 Setting ID number for RS−422.(Effective when option is installed.)
Initial value = 000000 Setting range : 000000 ~ 000009
・ FUNC−34 Setting transfer decimal point at transfer code for RS−232C and
RS−422. (Effective when option is installed)
Initial value = 000000 000000 = Without decimal point
000001 = With decimal point
・ FUNC−36 Selection of target for digital switch interface comparator
(Effective when option is installed.)
Initial value = 002222 0 = Display
1 = Net weight
2 = Gross weight
10
0
digit = Comparator S1
10
1
digit = Comparator S2
10
2
digit = Comparator S3
10
3
digit = Comparator S4
※ Each comparator S1, S2, S3 and S4 can be set individually
※ When “Display” is selected, “Load display value” becomes the target for comparator.
When “Net weight” is selected, “Net weight” value becomes the target for
comparator at the time of Tare is executing, and “Gross weight” value becomes the
target for comparator at the time of Tare is cancelled.
And when “Gross weight” is selected, “Gross weight” becomes the target for
comparator, whichever Tare is executed or not.