12
MULTIPLE CPU SYSTEM CONFIGURATION
12.3 Precautions for System Configuration
12 - 23
9
UTILITY OPERATION
10
FUNCTIONS AND
PROGRAMMING
11
OVERVIEW OF
MULTIPLE CPU
SYSTEM
12
MULTIPLE CPU
SYSTEM
CONFIGURATION
13
MULTIPLE CPU
SYSTEM
CONCEPT
14
COMMUNICATIONS
BETWEEN CPU
MODULES
15
PARAMETERS
ADDED FOR
MULTIPLE CPU
16
PRECAUTIONS FOR
USE OF AnS SERIES
MODULE
(3) Combination of power supply module, base unit and programmable
controller CPU
There are restrictions on the combination of the power supply module, base unit and
programmable controller CPU.
( Section 12.1.1)
(4) Precautions for GOT connection
The display devices applicable to the C Controller module are the same as the ones in
a single CPU system.
( Section 2.3 (5))
The following GOT connection is enabled when the programmable controller CPU is
set as a communication target in a multiple CPU configuration.
Refer to the GOT manual for details.
• Bus connection/direct CPU connection with programmable controller CPU in
multiple CPU configuration
• Connection with module controlled by programmable controller CPU in multiple
CPU configuration
(5) Precautions for MT Developer connection in multiple CPU system
configuration (For Version 00Y or earlier)
When a multiple CPU system includes the C Controller module as CPU No.1 and the
Motion CPU, the MT Developer's (Version 00Y or earlier) communication test cannot
be performed.(A Motion CPU communication test error (error code:12288))will occur.
Perform either of the following for testing the MT Developer's communication.
• Use MT Developer Version 00Z or later.
• When using MT Developer Version 00Y or earlier, CPU No.1 must be a
programmable controller CPU in the multiple CPU system.